Professional flooring or professional is a popular product in the field of construction. This material is widely used in the construction of the forms of various purposes. Many users have already rated the versatility of metal profiled sheets, performing fencing, partitions, mounted ceiling systems and so on. However, the root on private houses is faced with such a flooring. This is due to the excellent operational characteristics of the coating. After all, professional flooring has high strength, longevity, reliability, resistance to external aggressive conditions, as well as necessary aesthetic. Solving the finishing finish of the roof with the help of profiled sheets on their own, first of all, it is worth knowing how to calculate the roof career. After all, the issues of budget savings depend on the correct calculation, since purchasing only the required amount of material, and optimally placing it on the rods, it is possible to avoid a large number of waste and unnecessary sheets of sheets. It is also important to make the calculation of fasteners and other components. About how to do this and it is worth talking in more detail. First you need to decide on.

Technical characteristics of the professional sheet

Professor is a material produced from rolled steel of various thicknesses. The raw material passes through the lines of automated machines with special rollers, which give the finished product a characteristic profile. It should be known that the height of the corrugations can differ significantly. As a rule, the higher the profile, the stronger the material, also to enhance sheets, manufacturers can apply additional grooves on each wave acting as rigid ribs. For roofing systems, it is advisable to apply a professional flooring with high performance characteristics. Most often, such a product is marked as carrier material, that is, it has the code "H". Also from the labeling can be found:

  • the height of the corrugations;
  • metal thickness;
  • assembly width;
  • length of the product.

And some other important values, for example, type of coating and so on. However, to make the calcallation of the corrugation on the roof of these characteristics will be enough. Consider the standard values \u200b\u200bof 3 main parameters.
1. The height of the wave and its step. This parameter depends on. In particular, it is customary to distinguish the following varieties:

  • C - wall professional sheet (used for wall decoration and other cladding, profile height 8-44 mm);
  • H - carrying professional flooring (used to cover the roofs, installation of fences, while erecting bearing structures, the height of the corrugation is more than 44 mm);
  • NA - universal material (can be used as a product for facing work, for mounting partitions, roof coating, and so on, profile height 35-44 mm).

That is, you can purchase professional flooring, with a profile height from 8 to 114 mm, and the higher this parameter, the more durable is the material. As for the wave step, the value may also vary in the range of 4-20 cm. By performing the account of the professionalist, it is worth considering this parameter to know which value you can make a nest.

2. Width of the professional flooring. As a rule, the material of the sheet type it is customary to distinguish between two types of width. It:

  • general - that is, full size from the edge to the edge;
  • useful is the size, with a deduction of the adolescence, which is formed during installation, so this parameter is also called the mounting width.

As a rule, a useful width differs from a total of approximately 4-10 cm. Manufacturers indicate these parameters in the instructions for the material, as well as the recommended size of the allen when installing the product on the rods with different angles of inclination. The standard is considered width in the range from 98 to 185 cm.

3. Proflice length. Since this is a roller material, then the length can be quite large, including, you can purchase products to order. The parameters from 40 cm to 14.5 m are considered the same. Most convenient to work with sheets, the length of which is 3-4 m. It is recommended to choose such a professional flooring, the length of which would be equal to the length of the row plus the allowance for the backbone Sve. If the skates are quite large, then you can make an additional docking horizontally. At the same time, the concrete size of the allen will depend on. For example:

  • an angle of less than 15 degrees - overlap more than 20 cm;
  • angle of 15-30 degrees - Fall 15-20 cm;
  • an angle of more than 30 degrees - Fall 10-15 cm.

Counting professional flooring for roofing

Due to the fact that the professionalist is produced in various sizes, you can cover the roof from the skate to the edge of the sink by solid sheets. This eliminates the process of cutting sheets, as well as unnecessary joints in height. That is, to calculate the required amount of material, it is necessary to take into account such parameters as:

  • the width of the skate - is calculated along the length of the skate bar;
  • the length of the skate - the distance from the eaves to the skate plus anarchy sv.

To calculate the number of sheets, it is necessary to divide the width parameter to the utility width of 1 sheet of professional flooring. In this case, the resulting quantity should be rounded to an integer. In order to calculate the area (in sq.m) of the coatings, the resulting number of sheets should be multiplied by the length and total width. It is worth noting that it is fairly easy to calculate the amount of material for a simple single-pate or bantal roof. However, if there is a large number of rods of various shapes and additional elements, for example, in the form of mansard windows, the calculation is recommended to trust professionals. Since in this case it will be necessary to determine the area of \u200b\u200beach element, after which the drawing and already on the project calculate the required amount of material. It is important to say separately about. Their approximate flow will be 30-50 pieces per 1 sheet of professional flooring. That is, 1 sq m. Coatings are recommended to use 5-7 fasteners. In addition, 1-line meter of quiet elements will also need 3-5 self-tapping screws. Most conveniently produce calculations in special calculators programs that can be found on many specialized sites on the Internet.

Professional Calculation Programs

If your own engineering and mathematical skills are not confidence, it can always be enhanced in the calculations using special online calculators. In such programs, the calculation of the roof from the professional flooring is done quite quickly. In this case, the roof may even have a complex configuration, the automatic program will calculate the desired amount of material for each slope. To start working in one of these services, you should know certain parameters. In particular, we are talking about such values \u200b\u200bas:

  • length of the structure;
  • house width;
  • roof length;
  • roof height;
  • number of skates;
  • size of the soles with each side;
  • square of openings, if any.

When specifying all the values \u200b\u200bin the desired fields, you can easily calculate the roof parameters. If you need to know how many professional settings with certain parameters will be required to specific rods, then it is also necessary to make the following values \u200b\u200bin the program:

In addition, many online calculators make it possible to calculate the cost of materials, including the necessary. To determine this, it is enough to put the price for 1 sheet into a program or for 1 sq. M. product, as well as specify how much the packaging of the screws and, what amount of them in a pack. Then it remains only to watch the result of the calculations and go to the store for the acquisition of the required amount of products. However, it should be understood that when buying it is necessary to make a stock of materials, approximately 10%. This allows you to cut the sheets of professional flooring without excitement to spoil anything, and also do not save on fixing elements if such a need appears. After all, it is always better to strengthen the coating on the roof reliably, it will help to make work most effectively, and further operation as safe as possible.